| Parameters |
| Mounting Type |
Through Hole |
| Package / Case |
8-DIP (0.300, 7.62mm) |
| Surface Mount |
NO |
| Operating Temperature |
-40°C~85°C TA |
| Published |
2013 |
| JESD-609 Code |
e3 |
| Pbfree Code |
yes |
| Part Status |
Obsolete |
| Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
| Number of Terminations |
8 |
| ECCN Code |
EAR99 |
| Type |
Battery Backup Circuit |
| Terminal Finish |
Matte Tin (Sn) |
| Subcategory |
Power Management Circuits |
| Technology |
CMOS |
| Terminal Position |
DUAL |
| Peak Reflow Temperature (Cel) |
260 |
| Number of Functions |
1 |
| Terminal Pitch |
2.54mm |
| Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
| Output |
Push-Pull, Totem Pole |
| Pin Count |
8 |
| JESD-30 Code |
R-PDIP-T8 |
| Qualification Status |
Not Qualified |
| Supply Voltage-Max (Vsup) |
5.5V |
| Power Supplies |
3/5V |
| Number of Channels |
1 |
| Adjustable Threshold |
NO |
| Reset |
Active Low |
| Voltage - Threshold |
2.925V |
| Number of Voltages Monitored |
1 |
| Reset Timeout |
140ms Minimum |
| Supply Current-Max (Isup) |
0.07mA |
| Height Seated (Max) |
4.572mm |
| Length |
9.375mm |
| Width |
7.62mm |
| RoHS Status |
ROHS3 Compliant |
MAX802SEPA+ Overview
There are 8 terminals connected to this power management, which makes it easy to mount. As a reference, this IC management includes 1 functions for your convenience. There are a total of 1 channels on this supervisor, and they are arranged in a series. As a reference, this IC power includes 8-DIP (0.300, 7.62mm) functions for your convenience. As with other Battery Backup Circuit products, this IC management also offers a wide range of benefits. The package peak reflow temperature is specified to be 260. IC management is possible to find a succession of 1 voltages that have been checked. It is possible to subcategorize this power ic as a Power Management Circuits chip. Power management has a total of 8 pins. The recommended mounting type for IC management is Through Hole. The temperature of the supervisors should be set to this range: -40°C~85°C TA. During operation, this power management system outputs Push-Pull, Totem Pole. A power supply of 3/5V watts is required for the operation of this power management.
MAX802SEPA+ Features
Battery Backup Circuit type
MAX802SEPA+ Applications
There are a lot of Maxim Integrated MAX802SEPA+ Voltage Supervisors applications.
- Battery cars
- Power distribution systems of ICU
- Linux and server computing
- Solar power charger
- Leakage current detection
- Electric heating appliances
- Transformer load monitoring equipment
- WiFi router
- Kitchen appliances
- Functional modules