| Parameters | |
|---|---|
| Factory Lead Time | 18 Weeks |
| Mount | Chassis, Chassis Mount |
| Mounting Type | Chassis Mount |
| Package / Case | 120 |
| Operating Temperature | -20°C~70°C With Derating |
| Published | 2013 |
| Series | ECP180 (180W) |
| Size / Dimension | 4.00Lx2.00W x 0.84 H 101.6mmx50.8mmx21.6mm |
| Feature | Adjustable Output, Universal Input |
| Part Status | Active |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| Type | Open Frame |
| Applications | ITE (Commercial), Medical |
| Power (Watts) | 120W 180W Forced Air |
| Subcategory | Power Supply Modules |
| Max Power Dissipation | 120W |
| Number of Outputs | 1 |
| Approval Agency | EN, IEC, UL |
| Efficiency | 92% |
| Voltage - Isolation | 4kV |
| Output Voltage | 15V |
| Max Output Current | 8A |
| Voltage - Input | 85V~264VAC |
| Output Power | 120W |
| Protections | OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL |
| Min Input Voltage | 85V |
| Max Input Voltage | 264V |
| Current - Output 1 | 8A |
| Max Output Power | 120W |
| Minimum Load Required | No |
| Nominal Output Voltage | 15V |
| Ripple Voltage (Main Out) | 0.05303Vrms |
| Height | 21.336mm |
| Width | 50.8mm |
| REACH SVHC | Unknown |
| RoHS Status | ROHS3 Compliant |