| Parameters |
| Factory Lead Time |
5 Weeks |
| Mount |
DIN Rail, Panel |
| Mounting Type |
DIN Rail, Panel |
| Package / Case |
Module |
| Operating Temperature |
0°C~60°C |
| Packaging |
Bulk |
| Published |
2014 |
| Series |
CR4400 |
| Part Status |
Active |
| Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
| Max Operating Temperature |
60°C |
| Min Operating Temperature |
0°C |
| Voltage - Supply |
24V |
| Frequency |
50Hz~400kHz |
| Output |
Ratiometric, 0 V ~ 5 V |
| Current - Supply (Max) |
75mA |
| Polarity |
Bidirectional |
| Number of Channels |
2 |
| Polarization |
Bidirectional |
| Max Supply Current |
75mA |
| Accuracy |
±0.5% |
| Response Time |
250ms |
| Sensor Type |
Transformer w/Conditioning |
| For Measuring |
AC |
| Current - Sensing |
25A |
| RoHS Status |
ROHS3 Compliant |
CR4450-25 Overview
As a safety precaution, current sensors are placed in Module packages. For protection, these current sensors are packaged in a Bulk. They should be capable of supplying a maximum current of 75mA. There should be no current greater than 75mA coming from current sensors. To ensure proper operation of these current sensors, the operating temperature cannot be below 0°C. However, the maximum operating temperature for the current sensors should be 60°C.
CR4450-25 Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: 0°C~60°C
2 Channels
Mounting Type: DIN Rail, Panel
Sensor Type: Transformer w/Conditioning
Supply Voltage: 24V
Frequency: 50Hz~400kHz
Sensing Current: 25A
Module Package
CR4450-25 Applications
There are a lot of CR Magnetics Inc. CR4450-25 Current Sensors applications.
- Proving Switch
- Battery supplied applications
- Power factor correction
- Static converters for DC motor drives
- Mobile applications
- Continuity
- Battery chargers and systems
- Battery supplied applications
- Leakage Current Sensors
- AC variabel speed drives and servo motor drives