| Parameters | |
|---|---|
| Mounting Type | Through Hole |
| Package / Case | TO-247-3 |
| Supplier Device Package | TO-247AD |
| Operating Temperature | -40°C~175°C TJ |
| Packaging | Tube |
| Part Status | Obsolete |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| Input Type | Standard |
| Power - Max | 306W |
| Reverse Recovery Time | 50ns |
| Voltage - Collector Emitter Breakdown (Max) | 600V |
| Current - Collector (Ic) (Max) | 80A |
| Test Condition | 400V, 35A, 10Ohm, 15V |
| Vce(on) (Max) @ Vge, Ic | 1.95V @ 15V, 35A |
| Gate Charge | 75nC |
| Current - Collector Pulsed (Icm) | 105A |
| Td (on/off) @ 25°C | 40ns/105ns |
| Switching Energy | 300μJ (on), 630μJ (off) |
| RoHS Status | ROHS3 Compliant |